Identity
- Machine type
- X-ray
- Manufacturer
- Siemens Healthineers
- Model number
- Ysio Max
- Serial number
- 4512-882
- Asset tag
- AST-RAD-0142
- Department
- Radiology
- Location note
- Block B, Room 214, opposite the reporting room
- Installed
- 14 Mar 2021
- Status
- Operational
- Documents
- 4 files
Capable service teams
Siemens Healthineers vendor
MedTech Services vendor
Biomedical — internal team
Only these teams can be assigned when a service record is opened.
Preventive maintenance
Due in 18 days- Interval
- Every 6 months
- Last serviced
- 12 Jun 2026
- Next due
- 12 Dec 2026
- Cadence
- From schedule, not completion date
Service evidence
Photos can be attached when a record is opened and again at close-out.
Photos can be attached when a record is opened and again at close-out.
What you can see
Full service history and documents. Service costs are restricted to the service team and managers.
Full service history and documents. Service costs are restricted to the service team and managers.
| Date | Type | Service team | Technician | Duration | Parts | Cost | Notes |
|---|---|---|---|---|---|---|---|
| 12 Jun 2026 | Preventive | Siemens Healthineers | R. Menon | 3 h 20 m | — | ₹18,400 | Annual PM. Tube output and collimator alignment verified. |
| 04 Mar 2026 | Corrective | MedTech Services | S. Kumar | 6 h 05 m | Detector cable | ₹12,750 | Intermittent detector drop-out. Cable replaced, image quality verified. |
| 12 Dec 2025 | Preventive | Siemens Healthineers | R. Menon | 2 h 45 m | — | ₹18,400 | Routine six-month service. |
| 22 Aug 2025 | Calibration | Biomedical — internal | A. Rao | 1 h 30 m | — | ₹0 | Dose calibration against reference meter. Certificate uploaded. |
| 12 Jun 2025 | Preventive | Siemens Healthineers | R. Menon | 3 h 10 m | — | ₹17,200 | Routine six-month service. |
Showing the latest 5 of 9 records. Department users see everything except the cost column.
| Request | Raised | By | Urgency | Status | |
|---|---|---|---|---|---|
Detector not responding during exam REQ-204 |
07 Nov 2026 · 09:12 | Meera Nair | Urgent | Submitted | Open |
Collimator error on startup REQ-198 |
02 Mar 2026 · 14:40 | Meera Nair | Urgent | Resolved | Open |
Routine image quality check REQ-181 |
11 Aug 2025 · 10:05 | Dr. Latha Iyer | Routine | Resolved | Open |
Document library
Warranty papers, manuals, calibration certificates and reports. Named by whoever uploads them.
PDF
Warranty — extended cover to Mar 2028
PDF
User manual — Ysio Max operating instructions
PDF
Calibration certificate — Aug 2025
ZIP
Service reports 2021–2025
Upload and removal are limited to the service team and administrators. Max 25 MB per file · PDF, images, Office, text, ZIP. Files open in a new tab or download; nothing is versioned.
Installation · Mar 2021
Detector cable fault · Mar 2026
After cable replacement · Mar 2026
Room overview · Jun 2026